All Categories
Get it between 2024-12-17 to 2024-12-24. Additional 3 business days for provincial shipping.
ATO 1hp 110V VFD, 0.75 kW single phase 110V/120V input, single phase or three phase 220v output variable frequency drive. Running your 1 phase/3 phase motors on 120 volt supply via ATO VFD
【VOLTAGE& FREQUENCY】Input voltage: 1 phase 120V AC ±15%, Input frequency: 50Hz/60Hz, Output voltage: 1 phase or 3 phase 220V AC ±15%, Output frequency: 0.00~400.00Hz
【APPLICATION】ATO 110V input VFD Variable frequency drive can be widely applied to drive the AC motor, such as fans, pumps, power tools, etc.
【FUNCTION】ATO 120V input VFD inverter, with automatic energy save running, Automatic voltage regulation (AVR), Automatic current limiting function
【NOTE】The first step, please set "FE-00=0", after setting, the VFD will work as a normal frequency inverter, at this time the vfd can access AC power to work, so be sure to set "FE-00=0"(Please refer to the VFD quick setting or user manual)
【CUSTOMER FIRST】If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h
Specification: Basics Model GK3000-SP1S1-d75 Capacity 1 hp (0.75 kW) Shipping weight 3 kg Dimension 118*185*157 mm I/O Feature Rated current 4 A Input voltage 1 phase 120V AC ±15% Input frequency 50Hz/60Hz Output voltage 1 phase or 3 phase 220V AC ±15% Output frequency 0.00~400.00Hz Control Feature Control mode V/F control; vector control Communication Offer RS485 communication interface, support MODBUS-RTU communication protocol Speed regulation 1:100 Start torque 150% of rating torque at 1 Hz Speed control accuracy ≤±0.5% of rating synchronous speed Frequency precision Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% Frequency resolution Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz Torque boost Automatic torque boost, manual torque boost 0.1%~30.0% Interior PID controller Be convenient to make closed-loop system Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies. Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip Environment Enclosure rating IP 20 Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%