All Categories
STM- IV (A) stomo viscometer specification One.Summary The stom viscometer is used for the determination of paint and other KU indicating the viscosity of the coating. The instrument can display the KU value of the measured sample viscosity or the load value associated with the KU value (unit: G).Two.Specification 1. measurement range: 40.2 ~ 141.0KU (KU value), 27cP-5250cP 32 ~ 1099g (load value);2. measurement accuracy: 2.0% of full range; 3. measurement repeatability: the full range of 2.0%;4. the rotational speed of the mixing axis: 200r/min + 1r/min;5. container capacity: About 500ml;6. input voltage: 220V 50Hz;7. power: 10W;8. shape size: 210mm x 180mm x 500mm (long * width *);9. weight: 10kg.Three.Experimental environment 1. the instrument should be placed on a strong and smooth surface away from strong airflow, strong magnetic field, strong electric field and strong electric pulse interference.2. in order to ensure the safety of the operator, the power outlet in the laboratory should be grounded reliably.3. the temperature in the laboratory should be 23 C + 2 C, and the relative humidity should be less than 75%.4. sample should be 23 + 0.2 C. Four. Note1. there are precise measuring parts in the instrument cabinet.2. this instrument is a special instrument. Please do not open the instrument shell by itself, so as not to affect the accuracy of instrument measurement.3. instruments are temporarily unused, the lifting handle of the instrument should be kept on the high position limit unit, and it should not be placed in a lower position, otherwise the phenomenon of inflexibility may be produced.4. every year, companies should be checked regularly or sent to the metrological supervision department for testing once.Five.Packing list 1. host one;2. stainless steel cup;3.Manual4. power line