Electrode cleaning and arc calibration: 1. After the electrode installation is completed, turn on the fusion splicer power switch 2. After the fusion splicer enters the initial screen, press the menu button to enter the first level menu. 3. Find the machine maintenance by moving the cursor and enter the cleaning electrode item. After confirmation, the machine will automatically discharge the cleaning and aging electrode. 4. Install the cut left/right fiber, find the arc position item by the movement of the cursor, and keep the end face of the fiber and the tip of the two electrodes at the position of three points and one line by operation. The machine will perform the discharge test and adjust according to the actual situation. 5. Finally, press the menu button to launch in sequence. Note: Do not touch the tip of the electrode during the replacement process to prevent damage, and avoid the electrode falling inside the machine. The electrode position must be calibrated after the electrode is replaced. Package: 1x 1pair of fiber Fusion Splicer Electrode Rod for 50S 60S 80S