All Categories
Get it between 2024-12-06 to 2024-12-13. Additional 3 business days for provincial shipping.
KIT INCLUDES: Pair of 11" Class 00 Rubber Voltage Insulating Gloves; Pair of ArcGuard FR Knit Gloves; Pair of 10" Leather Protectors for gloves; Glove bag for easy storage
TESTED: Each pair of rubber voltage insulating gloves has a maximum use voltage of 500V AC/ 750V DC and is newly tested and stamped with test date; Rubber Voltage Insulating Gloves should be worn with leather protectors
COMPLIANT: Rubber Voltage Gloves are NFPA 70E-2015 compliant for arc flash; CSA Z462-15 compliant for arc flash (Canada); ANSI/ASTM D120, Class 00, Type 1; Max use voltage 500V AC/750V DC
ENHANCED PROTECTION: Ideal for arc flash & general FR applications; Utility Workers; Linemen; Constuction Workers; Power Generation; Electricians; Electrical Cooperatives; Contractors
ADDED COMFORT & PROTECTION: ArcGuard 12 Cal FR Knit Gloves can be worn with Rubber Voltage Gloves as a liner for added protection & comfort
ELECTRICAL SAFETY HOW IT SHOULD BE Enespro’s Class 00 Rubber Voltage Insulating Glove Kits are made with an insulating rubber that offers protection up to 500 Volts AC/750 Volts DC. These gloves are made of type 1 rubber and are available in sizes 8 to 12 and colors black, red and yellow. Arc flash hand protection – in one bag. The Class 00 Rubber Voltage Insulating Glove Kit Includes: 1 pair of newly tested Class 00 rubber voltage insulating gloves 1 pair of 10” leather protectors 1 pair of ArcGuard FR Knit Gloves 1 glove bag for convenient storage Protection at your Fingertips: Perfect for any job requiring Class 00 protection including utilities, electricians, linemen, construction, power generation, electrical cooperatives, and contractors. Stay Compliant: Always be sure you are wearing the correct level of protection while on the job. These Class 00 Rubber Voltage Gloves are NFPA 70E-2015 compliant for arc flash, CSA Z462-15 compliant for arc flash (Canada), and meet ANSI/ASTM D120. Important Information on Testing & Retesting: Gloves must be put into use within one year of the test date. If one year has passed since the gloves have been tested and they have not been open, they must be sent back for retesting. Once gloves are issued for use, they must be retested within 6 months from the date they were distributed to employees. Cleaning, Storage, and Inspection: Rubber voltage gloves should be cleaned in warm water with mild soap. When not in use, lay flat in protective bag – do not fold gloves. Avoid storing in areas with high heat or high moisture. Gloves should not be placed in direct sunlight. Inspections should occur before each use. Inspection methods are outlined in ASTM F1236. Technical Specs: Material: Type 1 Rubber Glove Sizes: 8-12 Colors: Black, Red & Yellow Maximum Use Voltage: 500V AC/ 750V DC Standards & Testing: Meets ANSI/ASTM D120 NFPA 70E-2015 Compliant for Arc Flash CSA Z462-15 Compliant for Arc Flash (Canada)