All Categories
Reporting Ranges: CO: 0-10.00%, HC (Hexane and Propane): 0-9,999 ppm, HC (Methane) 0.000-5.000%, CO2: 0-20.0%, O2: 0.0-25.0%, NO: 0-5000 ppm.
Accuracy: All gas channels +/-5% relative to gas reading.
Repeatability: All gas channels +/-3% full scale
Battery powered and self-contained infrared gas analyzer
Small, lightweight, and rugged with easy to read LED display
Fuel selection: Allows HC to be measured and displayed as Hexane for Gasoline, Propane for LPG, and Methane for CNG
Real time Lambda/air fuel ratio display using HC (Fuel dependent values are used), CO, CO2, O2 and NOx gas measurements
Real-time Combustion Efficiency display using HC (Fuel dependent values are used), CO, CO2, O2 and NOx gas measurements
Digital Analyzer with serial (RS232) PC/printer interface built-in
The Bridge Analyzer 5 Gas Analyzer measures Carbon Monoxide (CO), Carbon Dioxide (CO2), Fuel Dependent Hydro Carbons (HC), Oxygen (O2) and Nitric Oxide (NOx). The 5 Gas Analyzer comes in a hard case with all accessories as a complete, ready-to-use gas analyzer. Turn on the power switch, connect the hose and probe, push the Zero button. When the Zero is complete, the analyzer is ready to measure exhaust emissions gas. There are three power input options which will recharge the internal batteries. Accessories include a stainless steel probe assembly, easy storing sample line, and a built-in water trap and particulate filters to protect the internal infrared optics of the analyzer.