With temperature detection wire head: the temperature display range is -99°-999°, the unit C means Celsius temperature, and F means Fahrenheit temperature. The temperature unit can be switched by short pressing the "+" key
The total water consumption is expressed in liters in L and GAL in gallons, and the unit is passable.
Powered by AAA Batteries (Not Included): This system goes to sleep when left unattended and with no water flowing.
Total water consumption reset: There is a RESET symbol on the back of the circuit board with two contacts next to it. Shorting the two contacts after the system is powered on will clear the total water consumption. You can also press and hold the SET button, and after the number flashes, use the "+" and "-" signs to modify it to 0.
K value setting character (K SETTING): The K value setting character will be displayed when entering the K value setting interface
Note: 1. Main interface and settings under the main interface The characters TOTAL, total water consumption, temperature, total usage time, etc. will be displayed on the main interface. Long press the "SET" key in the main interface to set the total usage time. After long pressing the "SET" button, the first number of the total usage time will flash; short pressing the "+" flashing number will increase by 1; short pressing the "-" flashing number will decrease 1; short pressing the "SET" button will switch to next digit. After setting, long press the "SET" button to save the settings. Note: When setting the total usage time, it is set in hours by default. The total usage time in flowmeter mode and the total usage time in water pressure mode are independent. 2. K value setting interface and settings under K value setting interface (only flow meter mode) When the system works in flow meter mode, short press the "SET" key once in the main interface to jump to the K value setting interface. The character "K SETTING", the interface number 00, and the K value will be displayed under the K value setting interface. In the K value setting interface, long press the "SET" key to set the K value. After long pressing the "SET" key, the first digit of the K value will flash; short pressing the "+" flashing digit will increase by 1; short pressing the "-" flashing digit will decrease 1; short pressing the "SET" key will switch to the next digits. After setting, long press the "SET" button to save the settings. Specification: Operating voltage range: DC24V±8/1A Flow range: 1-30L/min, Water Pressure: ≤1.75Mpa LCD size: 3inch,built-in backlight; case size: 100*75*35mm (39.3*29.5*13.7inch) Solenoid valve working voltage: DC12V / 0.3A-0.5A (normally closed) Package Includes: 1 x LCD flow display controller 1 x G1/2 inch flowmeter