Pneumatic AFR2000 1/4 inch NPT Air Filter Pressure Regulator Kit (0 to 145 Psi) Air Tool Compressor Filter with Pressure Gauge

Product ID : 50182666


Galleon Product ID 50182666
Shipping Weight 0.75 lbs
I think this is wrong?
Model Fight For Honor030-033
Manufacturer
Shipping Dimension 8.7 x 2.99 x 2.2 inches
I think this is wrong?
-
1,359

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

Pneumatic AFR2000 1/4 inch NPT Air Filter Pressure Features

  • Air Filter Pressure Regulator

  • Air Filter Pressure Regulator Port Size:1/4"G ;Gauge Port Size:1/8“G

  • Air pressure reducer with particle filter and water separator, including semi-automatic drain

  • Filter the Tiny Particles and Moisture in the Air, Keep the Air Clean

  • Keep or Lower the Air Pressure


About Pneumatic AFR2000 1/4 Inch NPT Air Filter Pressure

Install and use 1 Please pay attention to clean the connecting pipes and joints during installation, so as not to bring dirt into the air duct 2 When installing, pay attention to whether the airflow direction is consistent with the direction indicated by the arrow on the fuselage, and pay attention to whether the connection and tooth shape are correct. 3 Pressure adjustment: Pull up the pressure adjustment knob and turn it clockwise to increase the pressure. Rotate counterclockwise, the pressure drops. Adjust to the desired pressure and press the pressure adjustment knob to lock it. 4. Water discharge: when there is no air pressure, water will be discharged automatically. When there is air pressure, push the water column upward to expel the water. After the draining is completed, loosen the draining column, the draining column will automatically pop up, and the draining is complete. When the water level exceeds the upper limit, please drain immediately, otherwise it will cause poor dehumidification. Maintain 1 Cleaning/replacement of the filter element: Take out the filter element, blow it from the inside out with air, and then use it again. 2 Transparent PC cup: Remove the PC cup and wipe it with a clean dry cloth. Do not use any chemicals that may damage the PC material.