Paladin 12 AWG Gauge Copper Stranded Building Wire
Paladin 12 AWG Gauge Copper Stranded Building Wire

Paladin 12 AWG Gauge Copper Stranded Building Wire 500' FT Roll THHN/THWN 600 Volt - UL Listed (Orange)

Product ID : 54682434
5 out of 5 stars


Galleon Product ID 54682434
UPC / ISBN 729958549637
Shipping Weight 12.57 lbs
I think this is wrong?
Model
Manufacturer Paladin
Shipping Dimension 7.4 x 7.24 x 5.87 inches
I think this is wrong?
-
Before ₱ 13,304
13,215

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

Paladin 12 AWG Gauge Copper Stranded Building Wire Features

  • #12 AWG Commercial Wiring for Outlets, Switches and Other Loads Contains 12 Gauge Stranded Copper (CU) Conductors

  • Can be Used in Wet or Dry Locations, Insulation is High Heat and Moisture Resistant Polyvinyl Chloride (PVC)

  • Jacket is Abrasion, Moisture, Gasoline and Oil Resistant Nylon

  • 100% Polyvinyl Chloride (PVC)

  • UL Listed, CSA Certified and RoHS Compliant


About Paladin 12 AWG Gauge Copper Stranded Building Wire

Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations. Features: - Nylon outer jacket for easy pulling and rated gasoline and oil-resistant II. - A tough, polyamide, Nylon outer jacket per UL-1063 and UL-83 - Can be used in wet and dry locations - UL listed, CSA certified and RoHS compliant Standards: - Underwriters Laboratories Standards UL-83, UL-1063 and UL-758 - AWM Spec 1316, 1317, 1318, 1319, 1320 and 1321 - ASTM Stranding Class B3, B8, B787 - Federal Specification A-A-59544 Canadian Standards Association C22.2 No. 75 - NEMA WC70/ICEA S-95-658 - Institute of Electrical and Electronics Engineers Construction: Conductors: Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8 Insulation: Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8 Specifications: Size: 12 AWG Number of Strands: 19 Cross Section Area (mm2): 3.31 PVC Insulation Thickness (Conductor): 0.380 mm / 0.015 inches Nylon Jacket Thickness: 0.100 mm / 0.004 inches Outside Diameter: 3.23 mm / 0.127 inches Allowable Ampacity: 20 Amps at 60, 75 and 90 degrees C