X
DIHOOL Ground Fault Circuit Breaker with Voltage
DIHOOL Ground Fault Circuit Breaker with Voltage
DIHOOL Ground Fault Circuit Breaker with Voltage
DIHOOL Ground Fault Circuit Breaker with Voltage
DIHOOL Ground Fault Circuit Breaker with Voltage
DIHOOL Ground Fault Circuit Breaker with Voltage
DIHOOL Ground Fault Circuit Breaker with Voltage
DIHOOL Ground Fault Circuit Breaker with Voltage
DIHOOL Ground Fault Circuit Breaker with Voltage

DIHOOL Ground Fault Circuit Breaker with Voltage Surge Arrester Protection, 63 Amp, 2 Poles, AC 120V-240V, DIN Rail Mount Residual Current Circuit Breaker

Product ID : 54857835


Galleon Product ID 54857835
Shipping Weight 0.77 lbs
I think this is wrong?
Model DZ47LED-2PE-63A-30MA
Manufacturer DIHOOL
Shipping Dimension 4.17 x 3.31 x 2.99 inches
I think this is wrong?
-
2,578

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

DIHOOL Ground Fault Circuit Breaker with Voltage Features

  • 5 Protection Functions: Overcurrent protection, Surge orotection, 30mA Leakage Protection, Short Circuit Protection, circuit isolation

  • Rated working voltage 120V/240V, rated current 63Amp, maximum voltage 500V, lightning protection Type 2 20kA,Leakage tripping current 30mA

  • Installation Method: 35MM DIN Rail, Product Size: 72MM x 95MM x 77MM, With 5pcs Terminals

  • After the circuit breaker wiring is completed, open the handle, and the red LED light and green LED light will light up to indicate normal operation. After powering on, press the T button to test the leakage function

  • Wiring: Upper input, Bottom output, with both input and output ground wires connected to the ground terminal simultaneously


About DIHOOL Ground Fault Circuit Breaker With Voltage

DZ47LED Residual Current Circuit Breaker (Lightning Residual Current Circuit Breaker), is miniature leakage circuit breaker with lightning protection device. It is suitable for distribution network with AC230V. For Lightning protection, overvoltage protection, overcurrent protection, leakage protection, short circuit protection, circuit isolation. DZ47LED Lightning Residual Current Circuit Breaker performance standards: GB16917.1 "Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs)-Part 1: General rules", GB 18802.2, IEC61643-1 and GB 500057 "Design code for protection of structures against lightning". Rated Current:63A Poles: 1P+N+PE Rated Voltage Ue: AC240V Insulation Voltage Ui: 500V Rated Frequency: 50/60Hz Rated sensitivity I△n: 30mA Short-circuit current Inc=l△c: 4500A Break time under I△n: ≤0.15 Residual current protection type: Electronic Terminal size top/bottom for cable: 25mm² Tightening torque:3.0Nm Thermo - Magnetic Release Characteristic:C-Curve (5-10In) Electrical Life: 2000 Mechanical Life: 10000