DIHOOL 6 Amp din Rail Mount Circuit Breaker, 12-240V dc Disconnect Switch for PV, UPS, RV Battery, Overload Protection, AC DC Universal

Product ID : 52310644


Galleon Product ID 52310644
Shipping Weight 0.44 lbs
I think this is wrong?
Model 3
Manufacturer DIHOOL
Shipping Dimension 3.5 x 3.23 x 1.65 inches
I think this is wrong?
-
1,355

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

DIHOOL 6 Amp din Rail Mount Circuit Features

  • DC 12-400V Protect - And + Pole or AC 90~400V Protect L And N Pole

  • Arc Extinguishing: DC arc extinguishing is more difficult than AC. This DC mini circuit breaker has a magnetic system to assist arc extinguishing.

  • Widely used in solar panel grid system to protect from damage caused by overcurrent caused by overload or short circuit. It can also be used for on-off of household AC120V/240V circuits

  • Size: 36MM x 80MM x 75MM, Fit for 35mm DIN rail.

  • Note:If you find that the screw part of the circuit breaker is burned, 99% of it is because the screw is not tightened


About DIHOOL 6 Amp Din Rail Mount Circuit

Product Specifications Model: DZ47X 2P 6A Rated Operating Voltage : DC 12V-400V And AC 90-400V Poles: 2P Rated Current: 6A breaking capacity: 4 kA Ics=Icu Trip Curve: B Mechanical Life: 10,000 times Electrical Life: 4,000 times Installation Method: 35MM DIN Rail Standard: IEC60898 / GB10936 Operating Temperature: -30°C to +70°C Operating Altitude: 2000 Meter Circuit Breaker Purchase Instructions The cause of the circuit breaker fire 1. The current is high and the cable is thin, and the cable heats up and causes a fire 2. Poor contact, the screws of the circuit breaker are not tightened, causing the screw part of the circuit breaker to heat up and catch fire (90% of the fire causes) Note: Be sure to tighten the screws -- important!!! 3. The quality of circuit breakers is poor. Our company selects A-level standard materials and flame-retardant shells for production. Each product is tested, and the quality pass rate reaches 99.5%. 4. Dust enters, humid environment; the circuit breaker is not waterproof and dustproof, try to use it in a waterproof box. Note:If you find that the screw part of the circuit breaker is burned, 99% of it is because the screw is not tightened —————————————————————— How to choose the current of the circuit breaker The current of the circuit breaker needs to be 20% larger than the working current. If the working current is 20A, Please choose 25A circuit breaker. If choose 20A, the circuit will trip and power off ——————————————————————