Panamax MB1500 home theater Uninterruptible power supply battery backup and power conditioner (discontinued by manufacturer)
Fully programmable, uninterrupted power supply, voltage Regulator and power conditioner
Linear Filtration eliminates loss of detail, pops and hisses to improve picture and sound quality
Ir control section indicator LED's - indicates status, IR output jacks - standard 1/8” (3.5mm) Mono Jack for connection to an IR flasher (IR flashers not included)
With over 30 years of innovation, millions of units Sold, multiple patents granted and numerous industry awards, Panamax is the recognized leader in AV equipment protection
1500 VA Rated Battery Backup
Voltage Regulation
AVM Automatic Voltage Monitoring
LiFT Linear Filtering Technology Noise Filtration
Four Programmable Critical Load Management AC Outlet Groups
From the Manufacturer From the Manufacturer The Panamax MB1500 Home Theater Uninterruptible Power Supply Battery Backup and Power Conditioner A UPS (Uninterruptible Power Supply) maintains power temporarily to ride out short black-outs or brown-outs preventing lengthy restart sequences. It allows safe shut down for extended black-outs. DVR’s can continue to record. Unique IR control (Patent Pending) allows ceiling projectors to cool their lamps properly to prevent damage from excessive heat before shutting down. Shuts off projection equipment via IR control Plays well with other devices Voltage Regulation (keeping voltage within nominal operating ranges) prevents equipment lock-ups due to power sags and keeps equipment from heating up (power supplies require more current when voltage is low). Plays well with others....as an add-on to every sale. Plug the M1500-UPS-PFP into the "Always On" outlet of any Panamax component to combine the award winning features of the component product with the enhanced features of the M1500-UPS-PFP. Total system capacity would be 15 amps. Front Panel Features Unsafe Voltage Indicator. This LED will illuminate to inform the user that an unsafe line voltage is present and that the UPS has switched to battery power. This could be either an over-voltage or an under-voltage. Line Fault Indicator. This LED will illuminate to warn the user that a wiring problem such as a bad/missing ground or reversed wiring exists within the AC receptacle. If illuminated, disconnect all equipment and contact an electrician to insure outlet is properly wired. Power On Indicator. This LED is illuminated when the utility condition is normal and the UPS outlets are providing clean, protected power. Removable Access Panel. Easy to remove for battery access and replacement. Test Switch. This UPS performs a self-test automatically when powered on. The test switch allows you to test the system at any time. In battery mode, you can press this button to silence an audible alarm. Battery Level Indicator. This is a visual indication of the battery charge. If battery capacity is under 20%, no indicator LED will illuminate and UPS starts beeping (if the audible alarm is enabled). Battery Mode Indicator. This illuminates during utility failure or an unsafe voltage condition, indicating that the battery is supplying power to the connected equipment. AVR Indicator. This indicates that the UPS is operating in automatic voltage regulation mode. When the LED is illuminated continuously, it indicates an input over-voltage and the UPS unit reduces the voltage to the normal operating range. When the LED is flashing, it indicates that the input line voltage is low and that the UPS is increasing voltage to the normal range. Load Level Indicator. This is a visual indication of the UPS load. The 1st arrow will illuminate when the load is above 25%, the 2nd above 50% and the 3rd above 75%. The 4th arrow will flash when the load is between 85% and 100%. Includes a bank of two UPS outlets (View larger) Back Panel Features Non-Critical-Load Outlets.Four battery powered, surge protected and AVR outlets for connected equipment insures temporary uninterrupted operation of connected equipment during a power failure. Critical Load Outlets. Two battery powered, surge protected and AVR outlets for critical-load equipment insures temporary uninterrupted operation of connected equipment during a power failure. IR Control Section. Learning Control Switches – Push to program or test the IR function. IR Detector Window – Receives the IR signal to be learned. Indicator LED’s – Indicates learning status. Output Delay Switches – Set the desired time delay between a power failure and when the IR signals are sent to the connected equipment. IR Output Jacks – Standard 1/8" (3.5mm) mono jack for connection to an IR flasher (IR flashers not included) Circuit Breakers for Overload Protection. Resettable circuit breakers provide optimal overload protection RS232