All Categories
Input Parameters---2hp 3 phase input output vfd, Input voltage:3 phase 240V /380V /460V AC ±15% (Optional), Input frequency: 50Hz/ 60Hz
Output Parameters---1.5 kW three phase output VFD variable frequency drive, Output voltage: 3 phase AC 0~input voltage, Output frequency: 0.00~400.00Hz
Advantages---220V/480V 3 Phase input VFD Inverter, with adjustable output frequency, Automatic energy save running, Automatic voltage regulation, Limit running current automatically to avoid frequent over-current which will cause trip
Wide range of applications---Three phase 220v/380v/480v vfd specialized designed for three phase induction motor, widely applied to control speed of the single phase motors, such as pumps, fans, power tools, etc.
Package Includes---1* three phase Variable Frequency Drive, 1*User Manual
Customer First---If you have no experience in driving a VFD, be sure to refer to the instructions before operating a VFD. If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h
ATO 2 hp (1.5 kW) VFD Inverter, three phase 240V, 415V, 480V VSD for choice, 3 phase sensorless vector variable frequency drive, RS485 enabled, strong overload capacity. ATO Three Phase Input Output VFD Specification: Capacity 2 hp (1.5 kW) Shipping weight 2 kg Dimension 190*104*150 mm I/O Feature Rated current 4 A Input voltage 3 phase 240V /415V /480V AC ±15% (Optional) Input frequency 50Hz/ 60Hz Output voltage 3 phase AC 0~input voltage Output frequency 0.00~400.00Hz Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds Control Feature Control mode V/F control; Sensorless vector control; Communication RS485 Speed regulation 1:100 Start torque 150% of rating torque at 1 Hz Speed control accuracy ≤±0.5% of rating synchronous speed Frequency precision Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% Frequency resolution Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz Torque boost Automatic torque boost, manual torque boost 0.1%~30.0% Interior PID controller Be convenient to make closed-loop system Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies. Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip Environment Enclosure rating IP 20 Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% Humidity 5%-95%, without condensation Altitude ≤1000m; VFD will be derated if above 1000m Impingement and oscillation Normal running: