All Categories
The AmScope T490A-PCT compound trinocular microscope has a sliding head, interchangeable pairs of 10x widefield and 16x widefield eyepieces, a forward-facing nosepiece with four DIN achromatic objectives, Brightfield/Darkfield/phase-contrast halogen illumination, and a double-layer mechanical stage with a stage stop to protect slides and objectives from damage. The trinocular viewing head has a vertical camera mount and a compensation-free binocular viewing head with interchangeable pairs of WF10x and WF16x eyepieces and sliding head to adjust inter-pupillary distance, a fixed 30-degree vertical inclination to reduce eye and neck strain, and a 360-degree rotation capability to provide a more comprehensive view and enable sharing. A Siedentopf binocular head enables the viewer to change the interpupillary distance without changing the tube length, eliminating the need to re-focus the image. It has an interpupillary range of 55 to 75mm to accommodate individual eye differences, and bi-lateral dioptric adjustment accommodates individual eye-strength differences. The vertical trinocular port accepts a camera with a 23mm or C-Mount adapter (camera sold separately). The forward-facing nosepiece has 4x, 10x, 40xS (spring), and 100xS (spring, oil) DIN achromatic optical-glass objectives that combine with the eyepieces to provide color correction of magnified images. The 40xS objective is spring loaded to prevent slide damage when focusing. The 100xS spring-loaded oil-immersion objective uses oil between the specimen and the objective lens to provide increased resolution over a standard objective. Four phase-contrast objectives (PH10x, PH20x, PH40x, and PH100x) combine with the eyepieces to provide phase contrast at eight magnifications. Plan objectives provide improved focus over the entire range of the viewing field. The objectives are mounted on a turret to ease magnification changes. A compound microscope is used for inspection and dissection of specimens when two-dimensional images are desired. The microscope has lower (transmitted, diascopic) Brightfield, Darkfield, and phase-contrast illumination that transmits light up through the specimen for enhanced visibility of translucent and transparent objects. Brightfield (BF) illumination allows the specimen to absorb light, resulting in a dark image on a light background, and Darkfield (DF) illumination reflects light off the specimen, resulting in a light image on a dark background. Phase-contrast provides high contrast and visibility without the use of stains, allowing specimens to be observed in their natural state without being killed or fixed. Halogen illumination provides bright light in a concentrated path and has a rheostat to control light intensity. The 1.25 NA Abbe condenser is mounted on a rack-and-pinion control system, can be adjusted to control the distance of the light from the stage, and has an iris diaphragm to optimize the amount of light illuminating the specimen. The 1.25 NA turret-type phase-contrast condenser has an iris diaphragm and Brightfield, Darkfield, and phase 1, 2, 3, and 4 positions. The double-layer mechanical stage, with 1mm stage divisions, locks the slide into place and provides precise slide manipulation along the X- and Y-axis to allow coordinates to be recorded, enabling the viewer to return to a specific location on the slide. A stage stop prevents the stage from coming into contact with the slide and objectives. The stage is 5-1/2 x 5-1/2 inches (140 x 140mm) and has a traveling range of 2-15/16 x 1-3/4 inches (75 x 45mm). Graduated coaxial coarse and fine focus has a focusing range of 1-3/16" (30mm) and fine-focus divisions of 0.002mm (0.0000787") that enable measurements to be taken. Focus knob tension control prevents the stage from drifting out of focus. The solid-metal enamel-coated body is durable and resistant to stains and corrosion. Specifications Head Compound trinocular Magnification 40x-1600x Trinocular port 23mm or C-Mo