AEMC L111 Simple Logger II, Single-Channel TRMS
AEMC L111 Simple Logger II, Single-Channel TRMS

AEMC L111 Simple Logger II, Single-Channel TRMS Current, 1A AC Input Range

Product ID : 44452447


Galleon Product ID 44452447
UPC / ISBN 685338140354
Shipping Weight 1.35 lbs
I think this is wrong?
Model L111
Manufacturer AEMC
Shipping Dimension 10.51 x 6.89 x 2.8 inches
I think this is wrong?
-
Save 57%
Before ₱ 35,139
15,230

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

AEMC L111 Simple Logger II, Single-Channel TRMS Features

  • Compatible standard current probes with voltage output and BNC connection

  • 64 Samples per cycle

  • Programmable storage rates from 8 every second to 1 every day

  • 3 User selectable storage modes

  • Stores up to 240000 measurements in non-volatile memory


About AEMC L111 Simple Logger II, Single-Channel TRMS

Simple logger II powered by standard alkaline batteries. Lightweight, compact, fits anywhere. 5 LED indicators quickly and clearly display logger status. Includes free DataView software for data storage, real-time waveform display, analysis and report generation. Isolated USB communication. USB cable included. 50V Cat. III. Applications: Load profiling, Fault current detection, Intermittent problem detection, Demand recording, Neutral current monitoring, Harmonic current monitoring using DataView software, Metering CT resizing, Start-Stop time stamping. Includes type A to 5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkaline batteries and user manual. Probes sold separately. input connection: Two recessed banana jacks. Current probe output voltage range 0 to 1V (probe dependent). Resolution: 0.1mV. Accuracy (50/60Hz): 0 to 10mV: unspecified, 10 to 50mV: +/-(0.5percent of Reading + 1mV), 50 to 1000mV: +/-(0.5percent of Reading + 0.5mV). Sample rate: 64 samples/cycle. Storage rate: Programmable from 125mS to 1 day. Storage modes: Start/Stop, FIFO and Extended Recording Mode (XRM"). Recording length: 15 minutes to 8 weeks, programmable using DataView. Memory: 240000 measurements (512KB) The recorded data is stored in non- volatile memory and retained even if the battery is low or removed. Communication: USB 2.0 optically isolated. Power source: 2 x 1.5V AA-cell Alkaline batteries. Battery life: 100 hrs to > 45 days (dependent on storage rate/recording length). Max conductor size. Current probe dependent. Case: UL94-V0. Vibration: IEC 68-2-6 (1.5mm, 10 to 55Hz). Operating Temperature: 14 to 122 degree F (-10 degree to 50 degree C). Storage temperature: -4 to 140 degree F (-20 degree to 60 degree C). Measures 2-3/4" width by 5-3/8" height by 1-17/64" depth.