AEMC L101 Simple Logger II, Single-Channel TRMS
AEMC L101 Simple Logger II, Single-Channel TRMS

AEMC L101 Simple Logger II, Single-Channel TRMS Current, 1V AC Input Range

Product ID : 6949565


Galleon Product ID 6949565
UPC / ISBN 685338140330
Shipping Weight 1.35 lbs
I think this is wrong?
Model L101
Manufacturer AEMC
Shipping Dimension 10.51 x 6.81 x 2.72 inches
I think this is wrong?
-
34,331

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown

Pay with

AEMC L101 Simple Logger II, Single-Channel TRMS Features

  • Compatible standard current probes with voltage output and BNC connection

  • 64 Samples per cycle

  • Programmable storage rates from 8 every second to 1 every day

  • 3 User selectable storage modes

  • Stores up to 240000 measurements in non-volatile memory


About AEMC L101 Simple Logger II, Single-Channel TRMS

Simple logger II powered by standard Alkaline batteries. Lightweight, compact, fits anywhere. 5 LED indicators quickly and clearly display logger status. Includes free DataView software for data storage, real-time waveform display, analysis and report generation. Isolated USB communication. USB cable included. 50V Cat. III. Applications: Load profiling, Fault current detection, Intermittent problem detection, Demand recording, Neutral current monitoring, Harmonic current monitoring using DataView software, Metering CT resizing, Start-Stop time stamping. Model L101 includes type A to 5-pin mini-B USB 2M, DataView CD, two 1.5V AA-cell Alkaline batteries and user manual. Probes sold separately. Current probe output voltage range 0 to 1V (probe dependent). Resolution: 0.1mV. Accuracy (50/60Hz): 0 to 10mV: unspecified, 10 to 50mV: +/- (0.5percent of Reading + 1mV), 50 to 1000mV: +/-(0.5percent of Reading + 0.5mV). Sample rate: 64 samples/cycle. Storage rate: Programmable from 125mS to 1 day. Storage modes: Start/Stop, FIFO and Extended Recording Mode (XRM"). Recording length: 15 minutes to 8 weeks, programmable using DataView. Memory: 240,000 measurements (512KB) The recorded data is stored in non- volatile memory and retained even if the battery is low or removed. Communication: USB 2.0 optically isolated. Power source: 2 x 1.5V AA-cell Alkaline batteries. Battery life: 100 hrs to >45 days (dependent on storage rate/recording length). Max conductor size. Current probe dependent. Case: UL94-V0. Vibration: IEC 68-2-6 (1.5mm, 10 to 55Hz). Operating Temperature: 14 degree to 122 degree F (-10 degree to 50 degree C). Storage temperature: -4 degree to 140 degree F (-20 degree to 60 degree C). Measures 2-3/4" width by 5-3/8" height by 1-17/64" depth.