X
Duda Energy HX115020:M200 B3-115A 20 Plate
Duda Energy HX115020:M200 B3-115A 20 Plate

Duda Energy HX115020:M200 B3-115A 20 Plate Stainless Steel Heat Exchanger with 2" Male NPT Ports Copper Brazed, 2.2" Height, 10" Width, 21.1" Length

Product ID : 38268145


Galleon Product ID 38268145
UPC / ISBN 840194118538
Shipping Weight 26.01 lbs
I think this is wrong?
Model HX115020:M200
Manufacturer Duda Energy
Shipping Dimension 21.1 x 10 x 2.2 inches
I think this is wrong?
-
76,844

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown

Pay with

Duda Energy HX115020:M200 B3-115A 20 Plate Features

  • Length: 21.1'', width: 10'', height: 2.2'', heat exchange area: 24.76Ft², with m8-1.25 mounting studs

  • Refrigeration capacity: 102000 - 680000 BTU/hour, design pressure: 435 psi, test pressure: 650 psi

  • Design temperature:-319°f to 430°f,304 stainless steel inner plates brazed with 99.9+ percent Pure copper

  • For refrigerants, water, oil, light alkali/acid, fuel, antifreeze, air & most liquids/fluids

  • Corrosion resistant, UL Listed, CE, ISO 9001:2008, tuvreinland ISO9001:2000


About Duda Energy HX115020:M200 B3-115A 20 Plate

Stainless steel plate heat exchangers . Brazed with 99.9+ percent Pure copper by Duda Energy . Plate heat exchangers have significantly good heat transfer rates because they use metal plates which have high heat conductivity rates and the plates are extremely thin. The plate heat exchangers also achieve high amounts of heat transfer through Convective forces with both working fluids. With large temperature differentials, great amounts of heat transfer can be achieved using a plate heat exchanger.This is an extremely popular unit for wood burning furnaces, radiant floor systems, refrigerant systems, straight vegetable oil conversions, beer chilling, air conditioning system and solar water heating systems. It will work for any application in which the desired result is for two fluids (liquid or gas) to exchange heat. Fluid a passes from the port on the left of the heat exchanger through every other channel created by the plates to the opposite end port on the left of the heat exchanger (looking at it the long way). fluid b passes from the port on the right through the other channels created by the plates and comes out the other port on the right side. The fluids are essentially touching each other through the plates and heat is transferred from the hot fluid to the cold fluid. (But the fluids do not mix).