All Categories
♦ Single timed output ♦ Accommodates four sensor probes ♦ Accommodates twelve annunciators ♦ Adjustable probe sensitivity ♦ Adjustable relay time ♦ Manual trip test button ♦ Retrigger hold-off
♦ Transient suppression ♦ Case and board may be purchased separately ♦ Includes CA-5 plug-in transformer ♦ Use with CT-6 probe ♦ Accommodates sounder: CT-A1, CT-11, CT-9
Power Required: 8-31 VAC or 10-41 VDC Standby Current: Under 1 mA Alarm Current: 45 mA maximum with one sounder (30 mA CT-GATE) Relay Contact Rating: Double Pole, Double Throw 1st Pole: 12 VDC, 200 mA for remotes 2nd Pole: SPDT, 5 amps at 30 VDC Relay Time: 1/2 to 15 Seconds
Temperature Range: 0F - 140F Dimensions: 5.5 inches by 5.5 inches by 2 inches
*NOTE: The CT-2B and CT-2BG are identical except the CT-2BG circuit board that is conformally coated with acrylic. This coating ensures the board is not affected by a change in temperature, allowing it to be installed in unheated applications such as garages, barns and gate operators.
This control unit has a single timed output and simplified features. Field adjustments include relay time and probe sensitivity. ♦ Single timed output ♦ Accommodates four sensor probes ♦ Accommodates twelve annunciators ♦ Adjustable probe sensitivity ♦ Adjustable relay time ♦ Manual trip test button ♦ Retrigger hold-off ♦ Transient suppression ♦ Case and board may be purchased separately ♦ Includes CA-5 plug-in transformer ♦ Use with CT-6 probe ♦ Accommodates sounder: CT-A1, CT-11, CT-9 Technical Specifications: Power Required: 8-31 VAC or 10-41 VDC Standby Current: Under 1 mA Alarm Current: 45 mA maximum with one sounder (30 mA CT-GATE) Relay Contact Rating: Double Pole, Double Throw 1st Pole: 12 VDC, 200 mA for remotes 2nd Pole: SPDT, 5 amps at 30 VDC Relay Time: 1/2 to 15 Seconds Temperature Range: 0F - 140F Dimensions: 5.5 inches by 5.5 inches by 2 inches *NOTE: The CT-2B and CT-2BG are identical except the CT-2BG circuit board that is conformally coated with acrylic. This coating ensures the board is not affected by a change in temperature, allowing it to be installed in unheated applications such as garages, barns and gate operators.