All Categories
Specificcation Input Voltage: Jumper selectable 95-132V ac or 190-264V ac Frequency: 50-60 Hz nominal Phase: 1 Output Voltage: Max 90V dc at 207V ac input Current: Continuous 4 A dc Intermittent 6 A for 10 secs Resistance: 15 ohms minimum Regulation +/-1.0% THERMAL DRIFT 0.05% per deg. C change in AVR ambient TYPICAL SYSTEM RESPONSE AVR response: 20 ms Filed current to 90%: 80 ms Machine Volts to 97%: 300 ms EXTERNAL VOLTAGE ADJUSTMENT +/-10% with 1 k ohm 1 watt trimmer UNDER FREQUENCY PROTECTION Set point: 95% Hz Slope: 170% down to 30 Hz UNIT POWER DISSIPATION 10 watts maximum BUILD UP VOLTAGE 4 Volts @ AVR terminals ENVIRONMENTAL Vibration: 20-100 Hz 50mm/sec 100Hz -2kHz 3.3g Operating Temperature:-40°C to + 60°C Storage Temperature:-55°C + 80°C Relative Humidity 0-70°C:95% Size: 13.4cm x 9.8cm x 3.5cm