All Categories
Get it between 2024-12-11 to 2024-12-18. Additional 3 business days for provincial shipping.
1. Multimeter: the module is mainly used for measuring AC voltage, current, active power, frequency, power factor and active energy, the module is without display function, the data is read through the RS485 interface and computer software.
2. Over power alarm: active power threshold can be set, when the measured active power exceeds the threshold, it can alarm.
3. Physical layer protocol: physical layer use UART to RS485 communication interface Baud rate is 9600, 8 data bits, 1 stop bit, no parity.
4. Application layer protocol: the application layer use the Modbus-RTU protocol to communicate. At present, it only supports function codes such as 0x03 (Read Holding Register), 0x04 (Read Input Register), 0x06 (Write Single Register), 0x41 (Calibration), 0x42 (Reset energy). etc.
5. Note: You can find the software download address in the file: user manual in the listing, run "RUN.BAT" and "PZEM014-Master" as administrator. If you have any problem about the product, please feel free to contaut us, we will reply you in 24 hours.
Overview This document describes the specification of the PZEM-014/016 AC communication module, the module is mainly used for measuring AC voltage, current, active power, frequency, power factor and active energy, the module is without display function, the data is read through the RS485 interface. 1.Function description 1.1 Voltage 1.1.1 Measuring range:80~260V 1.1.2 Resolution: 0.1V 1.1.3 Measurement accuracy: 0.5% 1.2 Current 1.2.1 Measuring range: 0~10A(PZEM-014); 0~100A(PZEM-016) 1.2.2 Starting measure current: 0.01A(PZEM-014); 0.02A(PZEM-016) 1.2.3 Resolution: 0.001A 1.3 Active power 1.3.1 Measuring range: 0~2.3kW(PZEM-014); 0~23kW(PZEM-016) 1.3.2 Starting measure power: 0.4W 1.3.3 Resolution: 0.1W 1.3.4 Display format: <1000W, it display one decimal, such as: 999.9W ≥1000W, it display only integer, such as: 1000W 1.4 Power factor 1.4.1 Measuring range: 0.00~1.00 1.4.2 Resolution: 0.01 5 Frequency 1.5.1 Measuring range: 45Hz~65Hz 1.5.2 Resolution: 0.1Hz 6 Active energy 1.6.1 Measuring range: 0~9999.99kWh 1.6.2 Resolution: 1Wh 1.6.4 Display format: <10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh ≥10kWh, the display unit is kWh, such as: 9999.99kWh 1.6.5 Reset energy: use software to reset