X
Category:
Conduits
Woods 55094221 25-Feet Ultratite-Type NM 1/2-Inch
Woods 55094221 25-Feet Ultratite-Type NM 1/2-Inch

Woods 55094221 25-Feet Ultratite-Type NM 1/2-Inch Non-Metallic Liquid Tight Flexible Conduit, Gray

Product ID : 4039230
4.7 out of 5 stars


Galleon Product ID 4039230
UPC / ISBN 032886045998
Shipping Weight 3.23 lbs
I think this is wrong?
Model 55094221
Manufacturer Southwire
Shipping Dimension 10.87 x 10.16 x 5.28 inches
I think this is wrong?
-
Save 14%
Before ₱ 2,564
2,216

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

Woods 55094221 25-Feet Ultratite-Type NM 1/2-Inch Features

  • Smooth interior for easy wire pulling

  • UV sunlight resistant jacket; rated for temperature range of -30-Degree C to 80-Degree C; 60-Degree C Oil (-22-DegreeF to +176-DegreeF; 140-DegreeF Oil)

  • Conduit seals out water; liquids; abrasives; alcohol; coolants; corrosive fumes and gases; grease; mineral acids; petroleum oils; salt air and spray

  • Accepts standard liquid-tight fittings for use with LFNC-B

  • Ideal for wet and outdoor locations and direct burial


About Woods 55094221 25-Feet Ultratite-Type NM 1/2-Inch

Ultratite-Type NM 1/2-Inch Non-Metallic Liquid tight Flexible Conduit. Liquid tight Flexible Nonmetallic Conduit. UL/CSA Listed. Oil-Resistant. Sunlight-Resistant. Crush-Resistant. Temperature Rated -30-Degree C to 80-Degree C. Ultratite Type NM is manufactured with a spiral of rigid PVC reinforcement imbedded within a flexible PVC wall. For the installation and protection of electrical conductors in circuits of 600-Volt nominal; or less. Motor circuits-for conductors of motor feeders; branch and control circuits. Applications requiring movement; crossover connections; or tight bends. For direct burial and encased in concrete. For flexible connections to swimming pool; spa; and hot tub motors per NEC 680.21A3 and 680.42A1. Electric signs and outline lighting supply and secondary-circuit conductors per NEC 600.7; 600.311000-Volt or less and 600.32 over 1000-Volt. In Hazardous Locations-where necessary for flexible connections within hazardous locations in accordance with the following:-Class I; Div. 2-NEC 501.10B2-Class II; Div. 1-NEC 502.10A2-Class II; Div. 2-NEC 502.10B2-Class III; Div. 1-NEC 503.10A2-Class III; Div. 2-NEC 503.10B. Floating building feeders and services per NEC 553.7. Boatyards and Marinas in accordance with NEC 555.13. Cranes and Hoists in accordance with NEC 610.11C. For Elevator; Dumbwaiters; Escalators; Moving Walks; Wheel Chair Lifts and Stairway Chair Lifts in accordance with NEC 620.21 where expressly permitted. Under raised floors in information technology equipment conductors and cables in accordance with NEC 645.5 D and 645.5D2. For containment of 600-Volt and lower potential circuits. Approved for use in lengths longer than 6-Feet per NEC 356.105. Motor leads per NEC 430.145B. NE Type designation-Type LFNC-B. ANSI / NFPA-70; NEC Article 356. UL Listed to Underwriters Laboratories Standard UL 1660. Approved by Canadian Standards Association.