X
Category:
Cooktops
Ramblewood 2 burner gas cooktop
Ramblewood 2 burner gas cooktop

Ramblewood 2 burner gas cooktop(Natural Gas), GC2-48N, ETL Safety Certified.

Product ID : 2533662
3.5 out of 5 stars


Galleon Product ID 2533662
UPC / ISBN 036336494909
Shipping Weight 18.65 lbs
I think this is wrong?
Model GC2-48N
Manufacturer RambleWood
Shipping Dimension 22.99 x 15 x 9.02 inches
I think this is wrong?
-
Save 5%
Before ₱ 25,656
24,266

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown

Pay with

Ramblewood 2 burner gas cooktop Features

  • ** ETL safety certified in US

  • Natural gas setting. LPG/Propane conversion burner orifice/valve included. Ceramic glass with heavy cast iron pot stand, sealed burner. Thermal couple module(Spanish Orkli) features flame out failure detection. Auto shut off gas supply

  • Electric ignition, 110V -120V AC input. Max. Power: Bottom Burner 5800 BTU, Top Burner 9500 BTU. Off-The-Grid feature allows burner to be light up by match in case of storm power outage

  • Cooktop dimension:12"(W) x 20"(D)


About Ramblewood 2 Burner Gas Cooktop

** ETL safety certified for US ** Natural gas setting. LPG/Propane conversion burner orifice/valve included Technician must exercise gas leakage test after installation ***After installation please check the burner caps(small black round disc on top of burner). Front burner(small one) should have the larger size burner cap. The back burner(with a ring outside) should have a smaller burner cap inside the ring. 90% of "flame does not stay lit" are caused by this cap misplacement*** Off-The-Grid feature allows burner to be light up by match in case of storm power outage. Thermal couple module(Spanish Orkli) features flame out failure detection. Auto shut off gas supply Cooktop glass dimension:12"(W) x 20"(D). Cut out dimension: 10.47 inch x 18.82 inch. Minimum depth clearance for installation: 3.5 inch depth measured from counter top surface. Improved design to eliminate Elbow connector in old model 4.9 ft power cord One year warranty. We process free exchange within 48 hrs for any defect reported at time of delivery & installation. Glass damaged is NOT included in warranty, except damaged by transportation/delivery. This is a gas unit that requires professional licensed technician to install per city/state safety code. Gas leakage test must be exercised prior to turning on the gas supply. The LPG/LP gas type setting model is GC2-48P,