X
Skyflame 1/2 Inch Straight Gas Key Valve Kit for
Skyflame 1/2 Inch Straight Gas Key Valve Kit for
Skyflame 1/2 Inch Straight Gas Key Valve Kit for
Skyflame 1/2 Inch Straight Gas Key Valve Kit for
Skyflame 1/2 Inch Straight Gas Key Valve Kit for
Skyflame 1/2 Inch Straight Gas Key Valve Kit for
Skyflame 1/2 Inch Straight Gas Key Valve Kit for
Skyflame 1/2 Inch Straight Gas Key Valve Kit for

Skyflame 1/2 Inch Straight Gas Key Valve Kit for Fire Pit Fireplace with Flange and 3 Inches Key, Chromed

Product ID : 31792888
4.7 out of 5 stars


Galleon Product ID 31792888
Shipping Weight 0.85 lbs
I think this is wrong?
Model SK-FD0027-SR1
Manufacturer Skyflame
Shipping Dimension 3.7 x 3.5 x 1.69 inches
I think this is wrong?
-
2,188

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

Skyflame 1/2 Inch Straight Gas Key Valve Kit for Features

  • For use with natural gas or liquid propane fuels; Rated at 150,000 BTU; 1/2 PSI

  • High capacity flow for best flame performance, 1/2 inch inlet and outlet with standard female NPT threads

  • Includes Quarter-Turn Ball Valve (brass), 3 inch Key and Floor Plate Flange (chromed)

  • Ball valves are superior to globe valves for on/off control without pressure drop

  • Perfect for homemade fire pit, fire bowl, fire table, fireplace project so on, very easy to use


About Skyflame 1/2 Inch Straight Gas Key Valve Kit For

Our 1/2 inch straight gas key valve kit is perfect for your gas fire pit or fireplace project. The valve is made of durable brass so that it can last whether installed indoors or outdoors. For use with up to 150,000 BTU of natural gas or propane. The included key promotes safety since without the key the valve cannot be operated. In addition, the valve utilizes standard 1/2 inch female national pipe thread on both its inlet and outlet so you shouldn't have any problem integrating it with your existing gas piping. The following are a few points for attention to the use of the product: The main valve for the gas line supply must be in the closed position. DO not use excessive torque on the gas valve during installation. Screw the gas valve onto the threaded gas supply pipe. Make sure the gas valve is in the closed position. Blow out all the grit, dirt or other foreign material from the gas supply line. Use a gas rated Teflon tape to seal all joints. Run an air pressure test (2 PSI) on the system to test for leaks. Apply soap water to all the joints to signal any evidence of leakage. Turn on the main gas supply and retest for evidence of any gas leakage.