All Categories
THE MEASURING PROCEDURE: This scanner set was measured with PANGOLIN QM2000 card. Running at the desired output speed. Using the standard ILDA test pattern. Laboratory power supply at +/-15VDC, room temperature. Windows PC with Pangolin,12/30k ILDA test frame, full size. 7x11x0.6mm mirror was used during measuring period. The galvos are fixed in the standard mounts on an aluminmum baseplate without forced cooling. 20kpps @ 20 degree 22kpps @ 15 degree 25kpps @ 10 degree 30kpps @ 8 degree 35kpps @ 5 degree POTENTIOMETER DESCRIPTION: IS: Input scale (adjusted only in factory) SG : Servo gain (power of the feedback signal for internal PID controller LFD : Low frequency damping (correct overshoot) HFD : High frequency damping (correct undershoot) LIN : Zero offset (electrical offset of the driver, adjusted only in factory) PS :Position scale (increases or decrease input sensitivity of the computer, DO NOT change it) STANDARD PACKAGE: 2× Scanners 2× Driver board 2× Mirrors 1× Scanner mount 1× Power supply (PUS) 2× Cables driver to scanner 2× Cables driver to PUS 2× Cables driver to input signals