X
Siemens B120DF 20-Amp, Afci/Gfci Dual Function
Siemens B120DF 20-Amp, Afci/Gfci Dual Function

Siemens B120DF 20-Amp, Afci/Gfci Dual Function Circuit Breaker, Bolt on Panel Board Style

Product ID : 48958707


Galleon Product ID 48958707
UPC / ISBN 887621817220
Shipping Weight 0.34 lbs
I think this is wrong?
Model B120DF
Manufacturer SIEMENS
Shipping Dimension 5.31 x 4.29 x 1.3 inches
I think this is wrong?
-
Save 54%
Before ₱ 23,664
10,832

*Price and Stocks may change without prior notice
*Packaging of actual item may differ from photo shown
  • Electrical items MAY be 110 volts.
  • 7 Day Return Policy
  • All products are genuine and original
  • Cash On Delivery/Cash Upon Pickup Available

Pay with

Siemens B120DF 20-Amp, Afci/Gfci Dual Function Features

  • Faster, more cost effective installation to meet code requirements compared to installing an AFCI breaker and GFI receptacle

  • Lower cost compared to AFCI breaker and GFCI receptacle

  • For use on Siemens panel boards that accept UL type BFGA2 breakers

  • Siemens exclusive LED trip indicator pinpoints cause of trip

  • HACR, SWD, 120 Volt AC rated


About Siemens B120DF 20-Amp, Afci/Gfci Dual Function

Description Two state-of-the-art technologies packaged in one small device - The Dual Function Circuit Breaker combines GFCI and AFCI, protecting against both Arc Faults and Ground Faults. This, along with the new Self Test & Lockout feature, makes it the first in class in electrical safety for homeowners. The 2014 National Electrical Code (NEC) now requires both Arc Fault and Ground Fault protection on kitchen and laundry circuits. Before the release of Dual Function Circuit Breakers, the only option to comply with this code was to pair an AFCI circuit breaker with a GFCI receptacle. The Dual Function Circuit breaker combines these two devices into one solution that provides both cost savings and less hassle in installation and maintenance. This is a win solution for everyone. A device that tests itself - Testing GFCIs and AFCIs on a monthly basis is a good idea that is sometimes forgotten. Underwriters Laboratories (UL) suggests that AFCI/GFCI devices be tested every 30 days after installation to ensure they are properly working. Now the new Self Test & Lockout feature enables the Dual Function Circuit Breaker to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground/arc fault. This effortless system guarantees that only the best protection is given to your home at all times.